Product Introduction
Climatic chamber, also known as Constant temperature and humidity chamber. Refers to a test box that can control temperature and humidity at the same time.. It is used to test the performance of materials in various environments and test the heat resistance, cold resistance, dry resistance and humidity resistance of various materials. It can be used for sample processing and quality testing of electronics, electrical appliances, mobile phones, communications, meters, vehicles, plastic products, metals, food, chemicals, building materials, medical care, aerospace, etc.
-
The shell is made of cold-rolled steel plate, the surface is electrostatic sprayed, the inner surface is mirror-finished stainless steel, and the double-layer tempered glass observation room is solid and durable;
-
Adopt microcomputer system intelligent control, LCD display control temperature, humidity, time, over-temperature alarm function;
-
Large-screen LCD display, multiple sets of data on one screen, menu-style operation interface, easy to understand and operate;
-
With PID automatic calculation function, the temperature and humidity change conditions can be corrected in time to ensure that the temperature and humidity control is more accurate and stable;
-
With 100 programs, 1000 segments, 999 cycle step setting capacity, to meet the needs of multi-program and multi-step experiments;
-
RS-485 communication interface is optional, providing convenience for computer terminal application;
Model | TH-50 | TH-150 | TH-250 | TH-500 | TH-800 | TH-1000 |
---|---|---|---|---|---|---|
Carrying bracket | 2 | 2 | 3 | 3 | 3 | 3 |
Voltage | AC220 /50HZ | AC220 /50HZ | AC220 /50HZ | AC220 /50HZ | AC380/ 50HZ | AC380/ 50HZ |
Working
temperature | RT +5~-35℃ | RT +5~-35℃ | RT +5~-35℃ | RT +5~-35℃ | RT +5~-35℃ | RT +5~-35℃ |
Input power | 1300W | 1600W | 2000W | 3500W | 5500W | 7500W |
Humidity probe | Capacitive digital | Capacitive digital | Capacitive digital | Capacitive digital | Capacitive digital | Capacitive digital |
Temperature
probe | Pt100 | Pt100 | Pt100 | Pt100 | Pt100 | Pt100 |
Humidity
deviation | ±3%RH | ±3%RH | ±3%RH | ±3%RH | ±3%RH | ±3%RH |
Temperature
fluctuation | ±0.5~1.0℃ | ±0.5~1.0℃ | ±0.5~1.0℃ | ±0.5~1.0℃ | ±0.5~1.0℃ | ±0.5~1.0℃ |
Temperature
resolution | 0.1℃ | 0.1℃ | 0.1℃ | 0.1℃ | 0.1℃ | 0.1℃ |
Humidity
control range | A:30-95%RH / B: 60-95%RH | A:30-95%RH / B: 60-95%RH | A:30-95%RH / B: 60-95%RH | A:30-95%RH / B: 60-95%RH | A:30-95%RH / B: 60-95%RH | A:30-95%RH / B: 60-95%RH |
Temperature
control range | A:5~85℃ / B: RT+10~85℃ / C:-10~85℃ / D:-20~85℃ | A:5~85℃ / B: RT+10~85℃ / C:-10~85℃ / D:-20~85℃ | A:5~85℃ / B: RT+10~85℃ / C:-10~85℃ / D:-20~85℃ | A:5~85℃ / B: RT+10~85℃ / C:-10~85℃ / D:-20~85℃ | A:5~85℃ / B: RT+10~85℃ / C:-10~85℃ / D:-20~85℃ | A:5~85℃ / B: RT+10~85℃ / C:-10~85℃ / D:-20~85℃ |